Logo

Waterproof Cable II

Comply with YD/T 1258.4、ICEA-596、GR-409 and IEC 60794 .

  • Features
  • Application
  • Structural parameters
  • Data Download

1. Good mechanical and environmental characteristics

2. Flame retardant characteristics meets the requirements of relevant standards

3. The mechanical characteristics meet the requirements of relevant standards

4. Soft, flexible, easy to splice, and with big capacity data transmission

5. Meet various requirements of market and clients

1. Used in indoor cabling

2. Used in pigtails and patch cords

3. Used in optical connections in equipment rooms and distribution frames

Fiber

Count

Dimension

(MM)

Weight

(kg/km)

Tensile (N)

LongTerm/Short Term

Crush(N/100mm)

LongTerm/Short Term

Min.Bend Radius(mm)

Dynamic / Static

Temperature (°C)

2

8.7

54

200

400

500

1000

20D

10D

-20+70

4

8.7

60

200

400

500

1000

20D

10D

-20+70

6

10.0

81

300

600

500

1000

20D

10D

-20+70

8

11.7

108

400

800

500

1000

20D

10D

-20+70

10

13.3

134

500

1000

500

1000

20D

10D

-20+70

12

15.0

183

600

1200

500

1000

20D

10D

-20+70

Note:  1. All the values in the table, which are for reference only, are subject to change without notice;

2.The cable dimension and weight are in accordance with tight-buffered fiber withφ0.9mm outer diameter;

3. Dis outer diameter of the round cable;

4.The minimum bend radius (static) is 5D when G.657 fiber is used.