Logo

Duplex Zipcord Cable

Used for the patchcord assembly, PVC/LSZH optional, compliance with UL OFNR, CPR Eca.

  • Features
  • Application
  • Structural parameters
  • Data Download

1. Good mechanical and environmental characteristics

2. Flame retardant characteristics meets the requirements of relevant standards

3. The mechanical characteristics meet the requirements of relevant standards

4. Soft, flexible, easy to splice, and with big capacity data transmission

5. Meet various requirements of market and clients


1. Used in pigtails and patch cords

2. Used in optical connections in equipment rooms and distribution frames


Fiber

Count

Dimension

(MM)

Weight

(kg/km)

Tensile (N)

LongTerm/Short Term

Crush(N/100mm)

LongTerm/Short Term

Min.Bend Radius(mm)

Dynamic / Static

Temperature (°C)

2

1.6x3.3

4.4

60

120

200

1000

50

30

-20+70

2

1.8x3.7

6.0

60

120

200

1000

50

30

-20+70

2

2.0x4.1

7.2

90

150

200

1000

50

30

-20+70

2

2.4x4.9

10.0

90

150

200

1000

50

30

-20+70

2

2.8x5.7

13.0

160

300

200

1000

60

30

-20+70

2

3.0x6.1

14.8

160

300

200

1000

60

30

-20+70